A review of the evidence on the effects and costs of implantable cardioverter defibrillator therapy in different patient groups, and modelling of cost-effectiveness and cost-utility for these groups in a UK context

Buxton M, Caine N, Chase D, Connelly D, Grace A, Jackson C, Parkes J, Sharples L
Record ID 32006000887
English
Authors' objectives:

The aims of this review were to update the systematic review evidence on the effectiveness, health-related quality of life (HRQoL) and cost-effectiveness of implantable cardioverter defibrillators (ICDs); compilation of new data on the service provision in the UK; and on the clinical characteristics, survival, quality of life and costs of ICD patients in the UK, and a new cost-effectiveness model using both international RCT and UK-specific data.

Authors' results and conclusions: None of the economic analyses in the studies found could be directly applied to the UK. The multiple sources of routine data available (including the national ICD database) provide an imperfect picture of the need for and use of ICDs. Implantation rates have been rising to a rate of around 20 per million population. Mean age is increasing and most ICDs are implanted into men aged 45-74 years. There is significant geographical variation. A survey of 41 UK centres provided additional evidence, particularly of variation in level of activity and resourcing. Most detailed data were obtained for 380 patients (89%). The postal survey produced a 73% response rate. Demographic characteristics of these patients were similar to ICD recipients in the UK as a whole and patients included in secondary prevention RCTs. Mean actuarial survival at 1, 3 and 5 years was 92%, 86% and 71%, respectively. Patient age at implantation and functional status significantly affected survival. Levels of most of the HRQoL measures were lower than for a UK general population There was no evidence of a change with time from implantation. Patients who had suffered ICD shocks had significantly poorer HRQoL. Most patients nevertheless expressed a high level of satisfaction with ICD therapy.
Authors' recommendations: The evidence of short- to medium-term patient benefit from ICDs is strong but cost-effectiveness modelling indicates that the extent of that benefit is probably not sufficient to make the technology cost-effective as used currently in the UK. One reason is the high rates of postimplantation hospitalisation. Better patient targeting and efforts to reduce the need for such hospitalisation may improve cost-effectiveness. Further cost-effectiveness modelling, underpinned by an improved ICD database with reliable long-term follow-up, is required. The absence of a robust measure of the incidence of sudden cardiac death is noted and this may be an area where further organisational changes with improved data collection would help.
Authors' methods: Systematic review
Details
Project Status: Completed
URL for project: http://www.hta.ac.uk/1208
Year Published: 2006
English language abstract: An English language summary is available
Publication Type: Not Assigned
Country: England, United Kingdom
MeSH Terms
  • Costs and Cost Analysis
  • Evidence-Based Medicine
  • Models, Economic
  • Defibrillators, Implantable
Contact
Organisation Name: NIHR Health Technology Assessment programme
Contact Address: NIHR Journals Library, National Institute for Health and Care Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK
Contact Name: journals.library@nihr.ac.uk
Contact Email: journals.library@nihr.ac.uk
Copyright: 2009 Queen's Printer and Controller of HMSO