Computer aided detection of breast cancer
Institute for Clinical Systems Improvement
Record ID 32004000664
English
Authors' objectives:
This review aims to assess the available evidence on the computer aided detection of breast cancer in mammography images.
Authors' recommendations:
With regard to computer aided detection (CAD) of breast cancer, the ICSI Technology Assessment Committee finds:
CAD causes no direct harm to patients. Misdiagnoses (false-positive or false-negative results) can lead to unnecessary follow-up testing, unnecessary patient anxiety, or delays in obtaining treatment. Lower numbers of false positive marks per image are typically observed for microcalcifications (0.20-0.30 marks/image) compared with masses (0.75-1.0 marks/image).
In two studies involving screening populations, between 10% and 16% of malignancies were detected by CAD alone and not detected by a radiologist. In one of these studies involving over 12,800 women, the detection rate for cancer increased 19% (from 3.2 to 3.8 cases per 1,000) with the addition of CAD. The evidence supports the use of CAD or a second reading by an independent radiologist to assure quality results.
For microcalcifications, the reported sensitivity of CAD is 98% to 100%. For masses, architectural distortions, and densities, the reported sensitivity is 67% to 90%. (Conclusion Grade II)
The radiologist remains the reader and interpreter of the mammogram. CAD assists the radiologist by identifying areas warranting further review.
In one study with 208 lesions, masses of 10 to 30 mm in diameter were more likely to be detected by a CAD system compared with either smaller or larger lesions.
The recall rate increased only slightly with the addition of CAD. Reported values ranged from 6.5% to 14.4% without CAD and 7.6% to 15.8% with CAD. The positive predictive value for predicting malignant histopathology on the biopsy was unchanged. Reported values ranged from 28% to 38%.
Data from one study suggest that CAD applied to digital mammography approximates the results achieved when CAD is applied to film-screen images.
Authors' methods:
Review
Details
Project Status:
Completed
URL for project:
http://www.icsi.org/knowledge/detail.asp?catID=107&itemID=1594
Year Published:
2004
English language abstract:
An English language summary is available
Publication Type:
Not Assigned
Country:
United States
MeSH Terms
- Diagnosis, Computer-Assisted
- Mammography
- Breast Neoplasms
Contact
Organisation Name:
Institute for Clinical Systems Improvement
Contact Address:
8009 34th Avenue South, Suite 1200, Bloomington, MN, USA. Tel: +1 952 814 7060; Fax: +1 952 858 9675
Contact Name:
icsi.info@icsi.org
Contact Email:
icsi.info@icsi.org
Copyright:
Institute for Clinical Systems Improvement (ICSI)
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.