Stance-control knee–ankle–foot orthoses for people with knee instability: a health technology assessment
Ontario Health
Record ID 32018001692
English
Authors' objectives:
This health technology assessment evaluates the effectiveness, safety, and cost-effectiveness of stance-
control knee–ankle–foot orthoses for people with knee instability. It also evaluates the budget impact of
publicly funding stance-control knee–ankle–foot orthoses and the experiences, preferences, and values
of people with knee instability.
Authors' results and conclusions:
Results
We included four studies in the clinical evidence review. We are uncertain if SCKAFOs improve walking
ability, energy consumption, or activities of daily living compared with LKAFOs (GRADE: Very low). Our
economic evidence review identified one costing analysis that suggested that the costs of orthotic devices
such as LKAFOs and SCKAFOs are highly variable according to the cost of materials, professional time, and customization required by the individual patient. The budget impact of publicly funding mechanical
SCKAFOs in Ontario over the next 5 years (at a full device cost of $10,784) ranged from an additional $0.50 million in year 1 (at an uptake rate of 30% in the target population [429 eligible people]) to $0.83 million in year 5 (at an uptake rate of 50%), with a total budget impact of $3.34 million over 5 years. We found that the greatest increase in budget impact in the scenario analysis came from the microprocessor SCKAFO device, which had an additional cost of $10.07 million in year 1, increasing to $16.78 million in year 5. When we decreased the cost of a mechanical SCKAFO device (to $7,384), this reduced the 5-year budget impact to $0.89 million (vs. $3.34 million in the reference case). The people with knee instability with whom we spoke reported that they preferred a device that would provide a more typical gait, but starting with this type of device would be easier than switching from an existing LKAFO.
Conclusions
We are uncertain if SCKAFOs improve walking ability, reduce energy consumption, or improve activities
of daily living compared with LKAFOs. We estimate that the additional cost to provide public funding for
a mechanical SCKAFO in people with knee instability would range from about $0.50 million in year 1 to
$0.83 million in year 5, yielding a total budget impact of $3.34 million over 5 years. Depending on the
class of SCKAFO and the uptake rate for the device, the budget impact may vary. People who met the
criteria for the use of a SCKAFO did have a strong preference for it over an LKAFO.
Authors' recommendations:
Ontario Health, based on guidance from the Ontario Health Technology Advisory Committee,
recommends publicly funding mechanical stance-control knee–ankle–foot orthoses for people
with knee instability
Authors' methods:
We performed a systematic literature search of the clinical evidence. We assessed the risk of bias of each
included study using the Risk of Bias in Nonrandomized Studies (RoBANS) tool and the quality of the body of evidence according to the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria. We performed a systematic economic literature search and also analyzed the budget impact of publicly funding SCKAFOs in people with knee instabilities in Ontario. We did not conduct a primary economic evaluation as there was limited comparative clinical evidence to inform an economic model. Our reference case budget impact analysis was done from the perspective of the Ontario Ministry of Health; it compared the total costs of a basic mechanical SCKAFO and locked KAFO (LKAFO) for people with knee instability. We also performed scenario analyses varying the following parameters: the price of all classes of SCKAFO (mechanical, electronic, and microprocessor), and the uptake of SCKAFO. To contextualize the potential value of SCKAFO, we spoke with people with knee instability.
Details
Project Status:
Completed
Year Published:
2021
URL for published report:
https://www.hqontario.ca/Portals/0/documents/evidence/reports/hta-stance-control-knee-ankle-foot-orthoses-for-people-with-knee-instability.pdf
Requestor:
OHTAC/Ministry of Health
English language abstract:
An English language summary is available
Publication Type:
Full HTA
Country:
Canada
Province:
Ontario
Pubmed ID:
34484485
MeSH Terms
- Ankle
- Foot Orthoses
- Patient Acceptance of Health Care
- Costs and Cost Analysis
- Joint Instability
- Knee Prosthesis
- Orthotic Devices
Keywords
- stance control
- knee orthoses
- foot orthoses
- ankle orthoses
- budget impact
- patient preferences
- health technology assessment
Contact
Organisation Name:
Ontario Health
Contact Address:
525 University Ave, Toronto, ON M5G 2L3
Contact Name:
Nancy Sikich, Director Health Technology Assessment
Contact Email:
oh-hqo_hta@ontariohealth.ca
Copyright:
The copyright for all Ontario Health publications is owned by the Queen’s Printer for Ontario. Materials
may be reproduced for commercial purposes only under a licence from the Queen’s Printer. For further
information or to request a licence to reproduce content, please contact:
Senior Copyright Advisor
Publications Ontario
416-326-5153
copyright@ontario.ca
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.