Acclarent eustachian tube balloon dilation for the treatment of eustachian tube dysfunction inadults

HAYES, Inc
Record ID 32018000008
English
Authors' recommendations: Eustachian tube dysfunction (ETD) is the inability of the eustachian tube (ET) to ventilate the middle ear, drain secretions, or protect the middle ear from sounds or pathogens in the nasopharynx. ETD is associated with otologic and rhinology symptoms, including tinnitus (ringing in the ears), aural fullness, an inability to equilibrate middle ear pressure, a sensation of being underwater, impaired hearing, pain, and balance problems. Description of Technology: The Aera Eustachian Tube Balloon Dilation (ETBD) System is the first balloon device approved for ETD in the United States. The Aera device consists of a guidance catheter and a 16 × 6 millimeter (mm) balloon. The blunttipped guidance catheter is inserted through the nose and advanced to the ET. The balloon is then advanced through the guidance catheter to the isthmus of the ET, which is at the end of the cartilaginous tissue prior to the bony portion. When the endoscopic marker is visualized at the distal end of the guidance catheter, the balloon is inflated to 12 atmospheres for 2 minutes and then withdrawn. Patient Population: The Aera ETBD System is indicated for ETBD for the treatment of persistent ETD in adults >= 22 years of age. Clinical Alternatives: Medical alternatives to the management of ETD include decongestants, oral and nasal steroids, antihistamines, pressure equalization methods, nasal douching, and antibiotics. The most common surgical intervention is the insertion of pressure-equalizing tympanostomy tubes, which may be used as short- or long-term treatment. Surgical interventions other than ETBD include transtubal application of fluids, eustachian tuboplasty using a laser or rotary cutting tool, laser coagulation, and myringotomy for direct application of topical steroids.
Details
Project Status: Completed
Year Published: 2017
English language abstract: An English language summary is available
Publication Type: Not Assigned
Country: United States
MeSH Terms
  • Adult
  • Catheterization
  • Dilatation
  • Ear Diseases
  • Eustachian Tube
Contact
Organisation Name: HAYES, Inc.
Contact Address: 157 S. Broad Street, Suite 200, Lansdale, PA 19446, USA. Tel: 215 855 0615; Fax: 215 855 5218
Contact Name: saleinfo@hayesinc.com
Contact Email: saleinfo@hayesinc.com
Copyright: Winifred S. Hayes, Inc
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.