                Authors' objectives:
                The measurement of nitric oxide (NO) concentration in expired breath has been introduced as an adjunct to or replacement for established clinical and laboratory assessments of asthma control to guide the management of asthma. Measurement of fractional exhaled nitric oxide (FENO) is a noninvasive diagnostic technique. The NO molecules exhaled in breath can be measured using a handheld electrochemical sensor or a large, stationary chemiluminescence gas analyzer.
Controversy: NO, which is normally produced by the respiratory tract mucosa, is believed to be a powerful mediator involved in airway inflammation. The level of FENO could serve as a surrogate indicator or marker of airway inflammation, providing information to guide changes in asthma medications as the severity of asthma worsens or resolves. Asthma is a complex disease that has many potential contributing factors. Measurement of FENO may not be enough information to guide asthma therapy since it detects only 1 contributing factor. Furthermore, FENO may only be accurate for patients who have certain types of asthma. Relevant Questions: Does measurement of exhaled NO provide information that improves the management of asthma? Is FENO measurement safe? Which patients might be suitable candidates for guidance of asthma therapy based on FENO levels?
            
                                                            
            Details
                        
                Project Status:
                Completed
            
                                                            
                Year Published:
                2016
            
                                    
                URL for published report:
                The report may be purchased from:http://www.hayesinc.com/hayes/crd/?crd=51426
            
                                                            
                English language abstract:
                An English language summary is available
            
                                    
                Publication Type:
                Not Assigned
            
                                    
                Country:
                United States
            
                                                
                        MeSH Terms
            - Humans
- Asthma
- Breath Tests
- Fractional Exhaled Nitric Oxide Testing
- Nitric Oxide
Contact
                        
                Organisation Name:
                HAYES, Inc.
            
            
                        
                Contact Address:
                157 S. Broad Street, Suite 200, Lansdale, PA 19446, USA. Tel: 215 855 0615; Fax: 215 855 5218
            
                                    
                Contact Name:
                saleinfo@hayesinc.com
            
                                    
                Contact Email:
                saleinfo@hayesinc.com
            
                                    
                Copyright:
                <p>HAYES, Inc.</p>
            
                    
                This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.