[Safety and efficacy of drug eluting balloon angioplasty for coronary artery stenosis: in-stent restenosis and de novo lesions]
Puñal Riobóo J, Sánchez González MC, Atienza Merino G
Record ID 32015000954
Spanish
Authors' objectives:
To evaluate safety and effectiveness of the drug-coated balloon (DCB) in PTCA in patients with ischemic disease due to coronary stenosis, either in-stent restenosis or de novo lesions.
Authors' recommendations:
Paclitaxel-eluting balloons appear to be more effective in treating in-stent restenosis than conventional balloon angioplasty whereas they did not show superiority when compared with paclitaxel-coated stents. There is
not enough evidence over safety and effectiveness of the use of drug-coated balloons in PTCA in de novo lesions. Further larger and well-designed studies with standard and latest comparators as second generation drug-eluting stents are needed to stablish an application in this setting.
Details
Project Status:
Completed
Year Published:
2015
URL for published report:
https://catalogobibliosaude.sergas.es/ASSCC711S_Linked_Documents/avalia-t201406_ACP_Balon-DEFINITIVO.pdf
English language abstract:
An English language summary is available
Publication Type:
Not Assigned
Country:
Spain
MeSH Terms
- Angioplasty, Balloon
- Coronary Restenosis
- Coated Materials, Biocompatible
- Carotid Stenosis
- Drug Therapy, Combination
- Carotid Arteries
Contact
Organisation Name:
Scientific Advice Unit, avalia-t; The Galician Health Knowledge Agency (ACIS)
Contact Address:
Conselleria de Sanidade, Xunta de Galicia, San Lazaro s/n 15781 Santiago de Compostela, Spain. Tel: 34 981 541831; Fax: 34 981 542854;
Contact Name:
avalia-t@sergas.es
Contact Email:
avalia-t@sergas.es
Copyright:
Galician Agency for Health Technology Assessment (AVALIA-T)
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.