Comparison of the effectiveness of inhaler devices in asthma and chronic obstructive airways disease: a systematic review of the literature

Brocklebank D, Ram F, Wright J, Barry P, Cates C, Davies L, Douglas G, Muers M, Smith D, White J
Record ID 32001000983
English
Authors' objectives:

To review systematically the clinical effectiveness and cost-effectiveness of inhaler devices in asthma and COPD.

Authors' results and conclusions: In vitro characteristics versus in vivo testing and clinical response: There is evidence that when comparative testing is performed on inhaler devices using the same methods, there is some correlation between particle size measurements and clinical response. However, the measurements are dependent upon the methods used, and a single measure of a device in isolation is of limited value. Also, there is little data on comparing devices of different types. There is currently insufficient data to verify the ability of in vitro assessments to predict inhaler performance in vivo. Effectiveness of metered-dose inhalers for the delivery of corticosteroids in asthma: The review of three trials in children and 21 trials in adults demonstrated no evidence to suggest clinical benefits of any other inhaler device over a pMDI in corticosteroid delivery. Effectiveness of metered-dose inhalers for the delivery of beta-agonists in stable asthma: In children, 11 studies were reviewed, of which seven compared the Turbohaler with the pMDI. One study found a significant treatment difference in peak expiratory flow rate, although there were differences in the patients baseline characteristics. In adults, a review of 70 studies found no demonstrable difference in the clinical bronchodilator effect of short-acting beta2-agonists delivered by the standard pMDI compared with that produced by any other DPI, HFA-pMDI or the Autohaler device. The finding that HFA-pMDIs may reduce treatment failure and oral steroid requirement in beta-agonist delivery needs further confirmatory research in adequately randomised clinical trials. Effectiveness of nebulisers versus metered-dose inhalers for the delivery of bronchodilators in stable asthma: In children, three included trials compared different devices with a nebuliser and demonstrated no evidence of clinical superiority of nebulisers over inhaler devices in bronchodilator delivery. A total of 23 studies in adults found equivalence for the main pulmonary outcomes and no evidence of difference in other outcomes. Effectiveness of metered-dose inhalers for the delivery of beta-agonists in COPD: Only two studies were included in this review. No evidence of clinical difference was found in beta-agonist delivery. Effectiveness of nebulisers versus metered-dose inhalers for the delivery of bronchodilators in COPD: Evidence from 14 trials demonstrated equivalence for the main outcomes of pulmonary function. For other outcomes there was no evidence of treatment difference in bronchodilator delivery. Patients ability to use metered-dose inhalers: Differences among studies and the heterogeneity of the results make it difficult to draw conclusions about inhaler technique differences between device types. The review of technique after teaching the correct technique suggests that there is no difference in patients ability to use DPI or pMDIs.
Authors' recommendations: This systematic review examined the evidence from clinical trials evaluating the clinical effectiveness of different inhaler devices in the delivery of inhaled corticosteroids and beta2-bronchodilators for patients with asthma and COPD. The evidence from the published clinical literature demonstrates no difference in clinical effectiveness between nebulisers and alternative inhaler devices compared to standard pMDI with or without a spacer device. The cost-effectiveness evidence therefore favours pMDIs (or the cheapest inhaler device) as first-line treatment in all patients with stable asthma unless other specific reasons are identified. Patients can use pMDIs as effectively as other inhaler devices as long as the correct inhalation technique is taught.
Authors' methods: Systematic review
Details
Project Status: Completed
URL for project: http://www.hta.ac.uk/1106
Year Published: 2001
English language abstract: An English language summary is available
Publication Type: Not Assigned
Country: England, United Kingdom
MeSH Terms
  • Asthma
  • Costs and Cost Analysis
  • Lung Diseases, Obstructive
  • Nebulizers and Vaporizers
Contact
Organisation Name: NIHR Health Technology Assessment programme
Contact Address: NIHR Journals Library, National Institute for Health and Care Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK
Contact Name: journals.library@nihr.ac.uk
Contact Email: journals.library@nihr.ac.uk
Copyright: 2001 Queen's Printer and Controller of HMSO
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.