Preoperative resting echocardiography for noncardiac surgery: a rapid review
McMartin K
            Record ID 32014001066
            English
                                    
                Authors' objectives:
                The objective of this rapid review was to determine the prognostic accuracy of preoperative resting 
echocardiography for noncardiac elective surgery with intermediate cardiac risk.
            
                                                
                Authors' recommendations:
                No studies were identified that examined the prognostic accuracy of resting echocardiography.
Resting echocardiography is not associated with improved survival or decreased length of stay after intermediate-risk, noncardiac, elective surgery (GRADE: Very low).
            
                                    
            Details
                        
                Project Status:
                Completed
            
                                                            
                Year Published:
                2014
            
                                    
                URL for published report:
                http://www.hqontario.ca/Portals/0/Documents/eds/rapid-reviews/rest-echocardiography-140305-en.pdf
            
                                                            
                English language abstract:
                An English language summary is available
            
                                    