Scottish trial of arthroplasty or reduction for subcapital fractures (STARS)- primary research

Keating JF, Grant A, Masson M, Scott NW, Forbes JF
Record ID 32001000699
English
Authors' objectives:

To compare internal fixation, bipolar hemiarthroplasty and total hip arthroplasty for the management of displaced subcapital fracture of the hip in previously fit patients of 60 years or older.

Authors' recommendations: In fit, older patients the results of the study show a clear advantage for arthroplasty over fixation; arthroplasty was more clinically effective and probably less costly over a 2-year period postsurgery. The results suggest that total hip replacement has long-term advantages over bipolar hemiarthroplasty, but these findings are less definite. This study provided support for the use of total hip replacement to treat displaced intracapsular hip fractures in fit, older patients. A larger trial comparing total versus hemiarthroplasty for these fractures could help to verify these findings. It would also be useful to know whether the findings of this study apply to patients aged 60 years or less who are usually treated with reduction and fixation. A clinical trial comparing arthroplasty versus fixation in patients older than 40 years would be a logical extension of the current study.
Details
Project Status: Completed
URL for project: http://www.hta.ac.uk/970
Year Published: 2005
English language abstract: An English language summary is available
Publication Type: Not Assigned
Country: England, United Kingdom
MeSH Terms
  • Arthroplasty
  • Femoral Fractures
Contact
Organisation Name: NIHR Health Technology Assessment programme
Contact Address: NIHR Journals Library, National Institute for Health and Care Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK
Contact Name: journals.library@nihr.ac.uk
Contact Email: journals.library@nihr.ac.uk
Copyright: 2009 Queen's Printer and Controller of HMSO
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.