Fluorouracil plasma monitoring: systematic review and economic evaluation of the My5-FU assay for guiding dose adjustment in patients receiving fluorouracil chemotherapy by continuous infusion
Freeman K, Connock M, Cummins E, Gurung T, Taylor-Phillips S, Court R, Saunders M, Clarke A, Sutcliffe P
            Record ID 32014000347
            English
                                    
                Authors' objectives:
                5-Fluorouracil (5-FU) is a chemotherapy used in colorectal, head and neck (H&N) and other cancers. Dose adjustment is based on body surface area (BSA) but wide variations occur. Pharmacokinetic (PK) dosing is suggested to bring plasma levels into the therapeutic range to promote fewer side effects and better patient outcomes. We investigated the clinical effectiveness and cost-effectiveness of the My5-FU assay for PK dose adjustment to 5-FU therapy.
To systematically review the evidence on the accuracy of the My5-FU assay compared with gold standard methods [high-performance liquid chromatography (HPLC) and liquid chromatography-mass spectrometry (LC-MS)]; the effectiveness of My5-FU PK dosing compared with BSA; the effectiveness of HPLC and/or LC-MS compared with BSA; the generalisability of published My5-FU and PK studies; costs of using My5-FU; to develop a cost-effectiveness model.
            
                                                
                Authors' recommendations:
                Using a linked evidence approach, My5-FU appears to be cost-effective at a willingness to pay of £20,000 per QALY for both mCRC and H&N cancer. Considerable uncertainties remain about evidence quality and practical implementation. RCTs are needed of PK versus BSA dosing in relevant cancers.
            
                                    
            Details
                        
                Project Status:
                Completed
            
                                    
                URL for project:
                http://www.nets.nihr.ac.uk/projects/hta/1311101
            
                                                
                Year Published:
                2015
            
                                    
                URL for published report:
                http://www.journalslibrary.nihr.ac.uk/hta/hta19910/#/abstract
            
                                                            
                English language abstract:
                An English language summary is available
            
                                    
                Publication Type:
                Not Assigned
            
                                    
                Country:
                England, United Kingdom
            
                                                
                        MeSH Terms
            - Predictive Value of Tests
- Plasma
Contact
                        
                Organisation Name:
                NIHR Health Technology Assessment programme
            
            
                        
                Contact Address:
                NIHR Journals Library, National Institute for Health and Care Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK
            
                                    
                Contact Name:
                journals.library@nihr.ac.uk
            
                                    
                Contact Email:
                journals.library@nihr.ac.uk
            
                                    
                Copyright:
                Queen's Printer and Controller of HMSO
            
                    
                This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.