An observational study of Donor Ex Vivo Lung Perfusion in UK lung transplantation: DEVELOP-UK

Fisher A, Andreasson A, Chrysos A, Lally J, Mamasoula C, Exley C, Wilkinson J, Qian J, Watson G, Lewington O, Chadwick T, McColl E, Pearce M, Mann K, McMeekin N, Vale L, Tsui S, Yonan N, Simon A, Marczin N, Mascaro J & Dark J
Record ID 32011001664
English
Authors' objectives: Many patients awaiting lung transplantation die before a donor organ becomes available. Ex vivo lung perfusion (EVLP) allows initially unusable donor lungs to be assessed and reconditioned for clinical use. The objective of the Donor Ex Vivo Lung Perfusion in UK lung transplantation study was to evaluate the clinical effectiveness and cost-effectiveness of EVLP in increasing UK lung transplant activity.
Authors' recommendations: Overall, one-third of donor lungs subjected to EVLP were deemed suitable for transplant. Estimated survival over 12 months was lower than in the standard group, but the data were also consistent with no difference in survival between groups. Patients receiving these additional transplants experience a higher rate of early graft injury and need for unplanned ECMO support, at increased cost. The small number of participants in the EVLP arm because of early study termination limits the robustness of these conclusions. The reason for the increased PGD rates, high ECMO requirement and possible differences in lung injury between EVLP protocols needs evaluation.
Details
Project Status: Completed
Year Published: 2016
English language abstract: An English language summary is available
Publication Type: Not Assigned
Country: England, United Kingdom
MeSH Terms
  • Lung
  • Lung Transplantation
  • Perfusion
  • Tissue and Organ Harvesting
  • Tissue Donors
Contact
Organisation Name: NIHR Health Technology Assessment programme
Contact Address: NIHR Journals Library, National Institute for Health and Care Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK
Contact Name: journals.library@nihr.ac.uk
Contact Email: journals.library@nihr.ac.uk
Copyright: <p>2011 Queen's Printer and Controller of HMSO</p>
This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.