                Authors' objectives:
                In high-income countries, 6% of all women will have sustained a fracture of the wrist (distal radius) by the age of 80 years and 9% by the age of 90 years. Advances in orthopaedic surgery have improved the outcome for patients: many such fractures can be treated in a plaster cast alone, but others require surgical fixation to hold the bone in place while they heal. The existing evidence suggests that modern locking-plate fixation provides improved functional outcomes, but costs more than traditional wire fixation.
            
                                                
                Authors' recommendations:
                Contrary to the existing literature, and against the increasing use of locking-plate fixation, this trial shows that there is no difference between Kirschner wires and volar locking plates for patients with dorsally displaced fractures of the distal radius. A Kirschner-wire fixation is less expensive and quicker to perform.
            
                                    
            Details
                        
                Project Status:
                Completed
            
                                    
                URL for project:
                http://www.hta.ac.uk/2233
            
                                                
                Year Published:
                2015
            
                                    
                URL for published report:
                http://www.journalslibrary.nihr.ac.uk/hta/hta19170/#/abstract
            
                                                            
                English language abstract:
                An English language summary is available
            
                                    
                Publication Type:
                Not Assigned
            
                                    
                Country:
                England, United Kingdom
            
                                                
                        MeSH Terms
            - Bone Plates
- Bone Wires
- Fracture Fixation
- Radius Fractures
- Wrist Injuries
Contact
                        
                Organisation Name:
                NIHR Health Technology Assessment programme
            
            
                        
                Contact Address:
                NIHR Journals Library, National Institute for Health and Care Research, Evaluation, Trials and Studies Coordinating Centre, Alpha House, University of Southampton Science Park, Southampton SO16 7NS, UK
            
                                    
                Contact Name:
                journals.library@nihr.ac.uk
            
                                    
                Contact Email:
                journals.library@nihr.ac.uk
            
                                    
                Copyright:
                <p>2011 Queen's Printer and Controller of HMSO</p>
            
                    
                This is a bibliographic record of a published health technology assessment from a member of INAHTA or other HTA producer. No evaluation of the quality of this assessment has been made for the HTA database.